That s why alternative fire suppression measures are often installed in server rooms.
Server room fire suppression options.
You can learn more about using a clean agent system in your server room here.
3m novec 1230 fire protection fluid is a clean agent fire extinguishant which was developed as a halon 1301 replacement and hydrofluorocarbon hfc alternative.
Novec 1230 is a leading product in fire protection for computer rooms data centres art galleries medical centres labs archives diesel generators and more.
What are your options.
We have listed below the most common fire suppression systems we install in the uk europe to protect server and comms.
The main server room fire suppression system of choice is a gas suppression system that.
Fire suppression systems or clean agent systems as they are sometimes referred to are designed to quickly alert you to a fire and extinguish that fire safely even when there is no one on the premises.
Is safe to use in occupied spaces.
Fire suppression systems are essential to the server room itself without any human intervention the system will automatically extinguish a fire immediately protecting one of the most expensive and valuable rooms in the building for many businesses.
Most it and data rooms are access controlled so the most reliable fire suppression option is to install an automatic fire protection system that can be deployed instantly when a fire occurs.
Clean agent systems are a great option for fire protection in server rooms.
Add portable ac units.
6 tips for server room fire suppression 1.
Another option for server room fire protection is an aerosol based system called stat x.
And reaches extinguishing levels in 10 seconds or less.
Fire suppression systems for data centres must be suitable for clean air environments as server rooms and data centres are mostly occupied by.
Typical causes of server room fires include electrical failure in the it equipment overheated electronics subfloor wiring malfunctions and.
Has minimal impact on the environment.
We will outline here the differences between clean agent systems and stat x systems to help you.
Traditional water based fire suppression systems are not usually viable solutions for it and data rooms because they can actually compound the ill.
Benefits of fitting fire detection and suppression.
A sprinkler system is the traditional fire suppression system installed in buildings but if you dose your servers in water that could destroy them just like fire.
Most systems use halon even though it has been shown to be environmentally unfriendly ozone.
Server room fire suppression technology has been around for as long as there have been server rooms.